Optimal design and ensuring the stable functioning the pretreatment systems and obtaining high-quality permeate for HD/HDF

  • B. Tkachuk Department of Industrial and Biomedical Electronics, National Technical University "Kharkiv Polytechnic Institute" https://orcid.org/0000-0002-4047-1582
  • V. Lisovyi Сommunal non-profit enterprise of Kharkiv regional council «Regional Medical Clinical Center of Urology and Nephrology n. a. V. I. Shapoval» https://orcid.org/0000-0002-2301-2229
  • M. Kolesnyk State Institute "Institute of Nephrology of the National Academy of Medical Sciences of Ukraine" https://orcid.org/0000-0001-6658-3729
  • E. Sokol Department of Industrial and Biomedical Electronics, National Technical University "Kharkiv Polytechnic Institute" https://orcid.org/0000-0003-1960-3445
  • R. Tomashevskyi Department of Industrial and Biomedical Electronics, National Technical University "Kharkiv Polytechnic Institute" http://orcid.org/0000-0002-5278-9272
  • N. Kotulevych Сommunal non-profit enterprise of Kharkiv regional council «Regional Medical Clinical Center of Urology and Nephrology n. a. V. I. Shapoval»
  • L. Mykhailiuk Сommunal non-profit enterprise of Kharkiv regional council «Regional Medical Clinical Center of Urology and Nephrology n. a. V. I. Shapoval»
Keywords: hemodialysis, water treatment system, reverse osmosis, permeate, standards, of quality filtration.

Abstract

Since 2011, at the Department of Industrial and Biomedical Electronics, NTU "KHPI" together with KNPE of KRC "RMCCUN n. a. V. I. Shapoval” with the participation of State Institute “Institute of Nephrology of the National Academy of Medical Sciences of Ukraine” is carrying out research aimed at improving patient safety the hemodialysis (HD)or hemodiafiltration (HDF) procedure. Especially prepared water ensures the safety and quality of the HD or HDF procedure. For the carrying-out, one HD session is necessary more than 150 liters of permeate. Poor quality permeates causes various complications, even can lead to fatal consequences. Therefore a constantly guaranteed qualitative permeate is an important component of safe HD or HDF.

Downloads

Download data is not yet available.

References

Tekhnolohiia pidhotovky vody, khronichnyi hemodializ, produktsiia dlia dializu Fresenius Medical Care [Internet]. Available from: URL: http://www.fresenius.com.ua/1981.htm. [In Ukrainian].

Tekhnolohyy y oborudovanye ochystky vodы dlia otdelenyi hemodyalyza [Internet]. Available from: URL: http://www.mediana-filter.ru/pdf/gemodializ.pdf. [In Ukrainian].

Dialysate for hemodialysis. ANSI/AAMI RD52:2004/(R)2010, Association for the Advancement for Medical Instrumentation, Arlington (VA) [Internet].; 2009. 54 p. Available from:  https://webstore.ansi.org/standards/aami/ansiaamird522004?gclid=CjwKCAiA-P7xBRAvEiwAow-VaVlvAWwWm8er4crQg-_nyCtrxUm-bpr3jM8rho4Dt8ucvPGuLPc-eBoCHLwQAvD_BwE

European Pharmacopoeia (Ph. Eur.) 9th Edition [Internet], 2018. 7072 p. http://online6.edqm.eu/ep900/

ISO 23500-3:2019 Preparation and quality management of fluids for haemodialysis and related therapies – Part 3: Water for haemodialysis and related therapies [Internet]. Available from: URL: https://www.iso.org/standard/67612.html.

DSanPiN 2.2.4-171-10 Derzhavni sanitarni normy ta pravyla „Hihiienichni vymohy do vody pytnoi, pryznachenoi dlia spozhyvannia liudynoiu. MOZ Ukrainy. Nakaz vid 12.05.2010 r. № 400 [Internet]. Available from:  URL: https://zakon.rada.gov.ua/laws/show/z0452-10. [In Ukrainian].

Shevelev F. A., Shevelev A. F. Tablicy dlja gidravlicheskogo rascheta vodoprovodnyh trub : s prav. posobie. – 6-e izd., dop. i pererab [Internet]. – M. : Strojizdat, 1984. – 116 s. Available from: https://www.petro-eng.ru/doc%20info/libr/tablica_cheveleva.pdf. [In Russian].

Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow BS EN 1717:2000 [Internet].  Available from: URL: https://shop.bsigroup.com/ProductDetail/?pid=000000000030194313.

Natsionalna dopovid pro yakist pytnoi vody ta stan pytnoho vodopostachannia v Ukraini u 2009 rotsi. Ministerstvo z pytan zhytlovo-komunalnoho hospodarstva Ukrainy. DP «NDKTI» MH [Internet].  Kyiv, 2010. 710 s. Available from: http://www.irbis-nbuv.gov.ua/cgi-bin/irbis64r_81/cgiirbis_64.exe?C21COM=2&I21DBN=VFEIR&P21DBN=VFEIR&Z21ID=&IMAGE_FILE_DOWNLOAD=1&Image_file_name=DOC%2FREP0000735.PDF.  [In Ukrainian].

Tipple MA, Shusterman N, Bland LA, et al. Illness in hemodialysis patients after exposure to chloramine contaminated dialysate. ASAIO Trans [Internet].  1991;37:588-591. Available from: https://www.ncbi.nlm.nih.gov/pubmed/1768494.

Snisar L.M., Liksunova L.O. Protokol kontroliu khimichnoi ta bakteriolohichnoi bezpeky vody dlia hemodializu/hemodiafiltratsii. Ukrainskyi Zhurnal Nefrolohii ta Dializu, 3(59) 2018, s.3-9. https://doi.org/10.31450/ukrjnd.3(59).2018.01. [In Ukrainian].

Likuvannia khvorykh na khronichnu khvorobu nyrok V PD stadii. Adaptovana klinichna nastanova, zasnovana na dokazakh ta unifikovani klinichni protokoly / Derzh. ustanova "In-t nefrolohii Nats. akad. med. nauk Ukrainy", Derzh. ekspert. tsentr M-va okhorony zdorovia Ukrainy, Nats. nyrkovyi fond Ukrainy ; [uklad.: Kolesnyk M. O. ta in.]. - Kyiv : Polihraf plius, 2016. - 242 s. [In Ukrainian].

Smeets E1, Kooman J, van der Sande F, Stobberingh E, and el. Prevention of biofilm formation in dialysis water treatment systems. Kidney Int. 2003 Apr;63(4):1574-6. DOI: https://doi.org/10.1046/j.1523-1755.2003.00888.x

Layman-Amato, R.L., Curtis, J., & Payne, G.M. (2013). Water treatment for hemodialysis: An update. Nephrology Nursing Journal [Internet]. 40(5), 383-404, 465. Available from: https://pdfs.semanticscholar.org/ac2d/cd63787c135e5f683d965a60c4cd006ae566.pdf

ISO 23500-2:2019 Preparation and quality management of fluids for haemodialysis and related therapies – Part 2: Water treatment equipment for haemodialysis applications and related therapies [Internet]. Available from: URL:  https://www.iso.org/standard/67611.html.


Abstract views: 750
PDF Downloads: 16474
Published
2020-01-14
How to Cite
Tkachuk, B., Lisovyi, V., Kolesnyk, M., Sokol, E., Tomashevskyi, R., Kotulevych, N., & Mykhailiuk, L. (2020). Optimal design and ensuring the stable functioning the pretreatment systems and obtaining high-quality permeate for HD/HDF . Ukrainian Journal of Nephrology and Dialysis, (1(65), 58-64. https://doi.org/10.31450/ukrjnd.1(65).2020.08